Generator
The generator (GEN) (10346):
supplies current to the vehicle's electrical system.
charges the battery (10655).
With the ignition switch in the RUN position:
voltage is supplied through the I circuit to the voltage regulator (VR) (10316).
the generator warning indicator turns on (lamp prove-out).
the voltage regulator turns on, allowing current to flow through the A circuit
to the generator field coil.
With the engine running:
the generator produces alternating current (ac), which is changed to direct
current (dc) by the rectifier diodes.
current is supplied to the vehicle through the generator B+ terminal (stud).
The generator warning indicator turns off.
Generator output is controlled by the voltage regulator.
Voltage Regulator
The voltage regulator (VR) (10316):
adjusts the generator field current to increase or decrease generator output
current.
sets the generator output voltage.
turns the generator warning indicator on when a problem is detected in the
charging system or associated wiring.
The generator output voltage will vary with temperature. The output voltage is
typically higher in the winter (cold) and lower in the summer (hot).
The voltage regulator will turn the generator warning indicator on for the
following conditions:
ignition switch in the RUN position with the engine not running. This is the
lamp prove-out (does not indicate a problem with the charging system)
open in the A circuit
inoperative generator (GEN) (10346)
generator output voltage too high
Refer to Section 14-00 for diagnostic procedures if the generator warning
indicator stays on with engine running.
With the system functioning normally:
the generator output current is determined by the voltage of the A circuit
(battery-sense voltage).
the A circuit voltage is compared to a set voltage internal to the voltage
regulator. The voltage regulator controls the generator field current to
maintain proper generator output.
the set voltage varies with temperature and is typically higher in the winter
than summer, allowing for better battery charging.
The generator warning indicator comes on when a problem is detected in the:
generator.
voltage regulator.
associated wiring.
Item | Specification |
---|---|
Generator (10346) | F5OU-AA |
Generator Rating (idle/max. rpm) | (130 Amp max) |
Generator Ratio (gen. crank/rev.) | 2.4:1 |
Regulator Type (10316) | Electronic/Integral with Generator |
Yes | No |
---|---|
GO to B2 | SERVICE excess voltage drop in Circuit 35 (O/LB). CHECK Alternator Fuse (30A) and connectors in Circuit 35 (O/LB) and SERVICE as required. |
NOTE: Voltage regulator must be connected to wiring harness for this test.
Yes | No |
---|---|
GO to B3 | SERVICE high resistance in Circuit 904 (LG/R). |
Yes | No |
---|---|
REPLACE generator. | CLEAN or SERVICE grounds as required. |