Generator
The generator (GEN) (10346):

supplies current to the vehicle's electrical system.
charges the battery (10655).
With the ignition switch in the RUN position:

voltage is supplied through the I circuit to the voltage regulator (VR) (10316).
the generator warning indicator turns on (lamp prove-out).
the voltage regulator turns on, allowing current to flow through the A circuit to the generator field coil.
With the engine running:

the generator produces alternating current (ac), which is changed to direct current (dc) by the rectifier diodes.
current is supplied to the vehicle through the generator B+ terminal (stud).
The generator warning indicator turns off.
Generator output is controlled by the voltage regulator.

Voltage Regulator
The voltage regulator (VR) (10316):

adjusts the generator field current to increase or decrease generator output current.
sets the generator output voltage.
turns the generator warning indicator on when a problem is detected in the charging system or associated wiring.
The generator output voltage will vary with temperature. The output voltage is typically higher in the winter (cold) and lower in the summer (hot).

The voltage regulator will turn the generator warning indicator on for the following conditions:

ignition switch in the RUN position with the engine not running. This is the lamp prove-out (does not indicate a problem with the charging system)
open in the A circuit
inoperative generator (GEN) (10346)
generator output voltage too high
Refer to Section 14-00 for diagnostic procedures if the generator warning indicator stays on with engine running.

With the system functioning normally:

the generator output current is determined by the voltage of the A circuit (battery-sense voltage).
the A circuit voltage is compared to a set voltage internal to the voltage regulator. The voltage regulator controls the generator field current to maintain proper generator output.
the set voltage varies with temperature and is typically higher in the winter than summer, allowing for better battery charging.
The generator warning indicator comes on when a problem is detected in the:

generator.
voltage regulator.
associated wiring.
 

SPECIFICATIONS

GENERATOR SPECIFICATIONS
Item Specification
Generator (10346) F5OU-AA
Generator Rating (idle/max. rpm) (130 Amp max)
Generator Ratio (gen. crank/rev.) 2.4:1
Regulator Type (10316) Electronic/Integral with Generator
 
NOTE: The voltage regulator (VR) (10316) is the only internally serviceable component on this generator (GEN) (10346) .
 

PINPOINT TEST B: SYSTEM OVERCHARGES (BATTERY BOILS OVER)

 

B1 CHECK VOLTAGE DROP IN A CIRCUIT

Is voltage drop less than 0.25 V?
Yes No
GO to B2 SERVICE excess voltage drop in Circuit 35 (O/LB). CHECK Alternator Fuse (30A) and connectors in Circuit 35 (O/LB) and SERVICE as required.

 

B2 CHECK VOLTAGE DROP IN I CIRCUIT

Is voltage greater than 1 V?
Yes No
GO to B3 SERVICE high resistance in Circuit 904 (LG/R).

 

B3 CHECK FOR POOR GROUNDS

Are all ground connections clean and tight?
Yes No
REPLACE generator. CLEAN or SERVICE grounds as required.

 